Real-time intravascular shear stress in the rabbit abdominal aorta.

Authors: Lisong Ai|||Hongyu Yu|||Wangde Dai|||Sharon L Hale|||Robert A Kloner|||Tzung K Hsiai

Journal: IEEE transactions on bio-medical engineering

Publication Type: Journal Article

Date: 2009

DOI: NIHMS366041

ID: 19527952

Affiliations:

Affiliations

    Department of Biomedical Engineering and Cardiovascular Medicine, University of Southern California, Los Angeles, CA 90089-1111, USA.|||||||||||||||

Abstract

Fluid shear stress is intimately linked with the biological activities of vascular cells. A flexible microelectromechanical system (MEMS) sensor was developed to assess spatial- and temporal-varying components of intravascular shear stress (ISS) in the abdominal aorta of adult New Zealand white (NZW) rabbits. Real-time ISS (ISS (real-time)) was analyzed in comparison with computational fluid dynamics (CFD) simulations for wall shear stress (WSS). Three-dimensional abdominal arterial geometry and mesh were created using the GAMBIT software. Simulation of arterial flow profiles was established by FLUENT. The Navier-Stokes equations were solved for non-Newtonian blood flow. The coaxial-wire-based MEMS sensor was deployed into the abdominal arteries of rabbits via a femoral artery cutdown. Based on the CFD analysis, the entrance length of the sensor on the coaxial wire (0.4 mm in diameter) was less than 10 mm. Three-dimensional fluoroscope and contrast dye allowed for visualization of the positions of the sensor and ratios of vessel to coaxial wire diameters. Doppler ultrasound provided the velocity profiles for the CFD boundary conditions. If the coaxial wire were positioned at the center of vessel, the CFD analysis revealed a mean ISS value of 31.1 with a systolic peak at 102.8 dyn x cm(-2). The mean WSS was computed to be 10.1 dyn x cm(-2) with a systolic peak at 33.2 dyn x cm(-2), and the introduction of coaxial wire increased the mean WSS by 5.4 dyn x cm(-2) and systolic peak by 18.0 dyn x cm(-2). Experimentally, the mean ISS was 11.9 dyn x cm(-2) with a systolic peak at 47.0 dyn x cm(-2). The waveform of experimental ISS was similar to that of CFD solution with a 30.2% difference in mean and 8.9% in peak systolic shear stress. Despite the difference between CD and experimental results, the flexible coaxial-wire-based MEMS sensors provided a possibility to assess real-time ISS in the abdominal aorta of NZW rabbits.


Reference List

    Chatzizisis YS, Coskun AU, Jonas M, Edelman ER, Feldman CL, Stone PH. Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling—Molecular, cellular, and vascular behavior. J Amer Coll Cardiol. 2007;49:2379–2393.|||Hove JR, Koster RW, Forouhar AS, Acevedo-Bolton G, Fraser SE, Gharib M. Intracardiac fluid forces are an essential epigenetic factor for embryonic cardiogenesis. Nature. 2003;421:172–177.|||Nonaka S, Shiratori H, Saijoh Y, Hamada H. Determination of left-right patterning of the mouse embryo by artificial nodal flow. Nature. 2002;418:96–99.|||Yamamoto K, Sokabe T, Watabe T, Miyazono K, Yamashita JK, Obi S, Ohura N, Matsushita A, Kamiya A, Ando J. Fluid shear stress induces differentiation of Flk-1-positive embryonic stem cells into vascular endothelial cells in vitro. Amer J Physiol Heart Circ Physiol. 2005;288:H1915–H1924.|||Wang H, Riha GM, Yan S, Li M, Chai H, Yang H, Yao Q, Chen C. Shear stress induces endothelial differentiation from a murine embryonic mesenchymal progenitor cell line. Arterioscler Thromb Vasc Biol. 2005;25:1817–1823.|||Ross R. Atherosclerosis is an inflammatory disease. Amer Heart J. 1999;138:S419–S420.|||Niebauer J, Cooke JP. Cardiovascular effects of exercise: Role of endothelial shear stress. J Amer Coll Cardiol. 1996;28:1652–1660.|||De Keulenaer GW, Chappell DC, Ishizaka N, Nerem RM, Alexander RW, Griendling KK. Oscillatory and steady laminar shear stress differentially affect human endothelial redox state: Role of a superoxide-producing NADH oxidase. Circ Res. 1998;82:1094–1101.|||Hwang J, Rouhanizadeh M, Hamilton RT, Lin TC, Eiserich JP, Hodis HN, Hsiai TK. 17 beta-Estradiol reverses shear-stress-mediated low density lipoprotein modifications. Free Radical Biol Med. 2006;41:568–578.|||Stone PH, Coskun AU, Kinlay S, Clark ME, Sonka M, Wahle A, Ilegbusi OJ, Yeghiazarians Y, Popma JJ, Orav J, Kuntz RE, Feldman CL. Effect of endothelial shear stress on the progression of coronary artery disease, vascular remodeling, and in-stent restenosis in humans—In vivo 6-month follow-up study. Circulation. 2003;108:438–444.|||Chatzizisis YS, Jonas M, Coskun AU, Beigel R, Stone BV, Maynard C, Gerrity RG, Daley W, Rogers C, Edelman ER, Feldman CL, Stone PH. Prediction of the localization of high-risk coronary atherosclerotic plaques on the basis of low endothelial shear stress—An intravascular ultrasound and histopathology natural history study. Circulation. 2008;117:993–1002.|||Taylor TW, Yamaguchi T. 3-dimensional simulation of blood-flow in an abdominal aortic-aneurysm—Steady and unsteady flow cases. J Biomech Eng, Trans ASME. 1994;116:89–97.|||Raghavan ML, Vorp DA, Federle MP, Makaroun MS, Webster MW. Wall stress distribution on three-dimensionally reconstructed models of human abdominal aortic aneurysm. J Vasc Surg. 2000;31:760–769.|||Roschke EJ, Harrison EC. Fluid shear stress in prosthetic heart valves. J Biomech. 1977;10:299–311.|||Gu YJ, Boonstra PW, Graaff R, Rijnsburger AA, Mungroop H, van Oeveren W. Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: A comparison between hollow fiber and flat sheet membrane oxygenators. Artif Organs. 2000;24:43–48.|||Song XW, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics. J Fluids Eng, Trans ASME. 2004;126:410–418.|||Hsiai TK, Hwang J, Barr ML, Correa A, Hamilton R, Alavi M, Rouhanizadeh M, Cadenas E, Hazen SL. Hemodynamics influences vascular peroxynitrite formation: Implication for low-density lipoprotein apo-B-100 nitration. Free Radic Biol Med. 2007;42:519–529.|||Hwang J, Ing MH, Salazar A, Lassegue B, Griendling KK, Navab M, Sevanian A, Hsiai TK. Pulsatile vs. oscillatory shear stress regulates NADPH oxidase system: Implication for native LDL oxidation. Circ Res. 2003;93:1225–1232.|||Ho CM, Tai YC. Micro-electro-mechanical-systems and fluid flows. Annu Rev Fluid Mech. 1998;30:579–612.|||Soundararajan G, Rouhanizadeh MM, Yu H, Kim ES, Hsiai TK. MEMS sensors for microcirculation. Sens Actuators. 2005;118:25–32.|||Rouhanizadeh M, Soundararajan G, Ascara D, Lo R, Browand F, Hsiai T. MEMS sensors to resolve spatial variations in shear stress in a 3-D bifurcation model. IEEE Sens J. 2006 Feb;6(1):78–88.|||Liu C, Huang JB, Zhu ZJ, Jiang FK, Tung S, Tai YC, Ho CM. Micromachined flow shear-stress sensor based on thermal transfer principles. J Microelectromech Syst. 1999;8:90–99.|||Meng EF, Tai YC. Polymer MEMS for micro fluid delivery systems. Abstracts Papers Amer Chem Soc. 2003;226:U383–U383.|||Liu C. Recent developments in polymer MEMS. Adv Mater. 2007;19:3783–3790.|||Yu H, Ai L, Rouhanizadeh M, Patel D, Kim ES, Hsiai TK. Flexible polymer sensors for in vivo intravascular shear stress analysis. IEEE/ASME J Microelectromech Syst. 2008 Oct;17(5):1178–1186.|||Kim TD, Seo TW, Barakat AI. Numerical simulations of fluid mechanical interactions between two abdominal aortic branches. Korea-Australia Rheol J. 2004;16:75–83.|||Ermolaev YA, Ra M. Potential of aortic current in rabbit. Biulleten Eksperimentalnol Biol I Med. 1974;77:6–8.|||GAMBIT 2.3 User’s Guide. F. I. Fluent, Inc; Lebanon, NH: 2006.|||Longest PW, Kleinstreuer C, Truskey GA, Buchanan JR. Relation between near-wall residence times of monocytes and early lesion growth in the rabbit aortoceliac junction. Ann Biomed Eng. 2003;31:53–64.|||Lorenzini G. Blood velocity field numerical assessment using a GPL code in case of intravascular Doppler catheter affections: Comparative analysis of different rheological models. J Biomech. 2005;38:2058–2069.|||Armstrong RC, Bird RB, Hassager O. Fluid Mechanics. Vol. 1. New York: Wiley; 1977. Dynamics of polymeric liquids; p. 470.|||Boger DV. Viscoelastic flows through contractions. Annu Rev Fluid Mech. 1987;19:157–182.|||Buchanan JR, Kleinstreuer C, Hyun S, Truskey GA. Hemodynamics simulation and identification of susceptible sites of atherosclerotic lesion formation in a model abdominal aorta. J Biomech. 2003;36:1185–1196.|||FLUENT 6.2 User’s Guide. F. I. Fluent, Inc; Lebanon, NH: 2006.|||Banerjee RK, Back LH, Back MR. Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses. Biorheology. 2003;40:613–635.|||Banerjee RK, Back LH, Back MR, Cho YI. Catheter obstruction effect on pulsatile flow rate-pressure drop during coronary angioplasty. J Biomech Eng, Trans ASME. 1999;121:281–289.|||Roy AS, Back LH, Banerjee RK. Guidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis. J Biomech. 2006;39:853–864.|||Hillewaert W, Courtens K, McLaughlin M, Wauters J, Wilmer A, Bijnens B, Claus P, Verdonck P, Devos P, Segers P. Numerical assessment of the impact of a flow wire on its velocity measurements. Ultrasound Med Biol. 2006;32:1025–1036.|||Krams R, Wentzel JJ, Cespedes I, Vinke R, Carlier S, Van Der Steen AF, Lancee CT, Slager CJ. Effect of catheter placement on 3-D velocity profiles in curved tubes resembling the human coronary system. Ultrasound Med Biol. 1999;25:803–810.|||Ai L, Yu H, Li R, Yu H, Paraboschi A, Hsiai T. Optimization of intravascular shear stress assessment in the abdominal aorta of New Zealand White Rabbits. submitted for publication.|||Rouhanizadeh M, Lin TC, Arcas D, Hwang J, Hsiai TK. Spatial variations in shear stress in a 3-D bifurcation model at low Reynolds numbers. Ann Biomed Eng. 2005;33:1360–1374.|||Ku DN. Blood flow in arteries. Annu Rev Fluid Mech. 1997;29:399–434.|||Dash RK, Jayaraman G, Mehta KN. Estimation of increased flow resistance in a narrow catheterized artery—A theoretical model. J Biomech. 1996;29:917–930.|||Roy AS, Banerjee RK, Back LH, Back MR, Khoury S, Millard RW. Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements. Amer J Physiol Heart Circ Physiol. 2005;289:H392–H397.|||Wentzel JJ, Krams R, Van Der Steen AFW, Li W, Cespedes EI, Bom N, Slager CJ. Disturbance of 3-D velocity profiles induced by IVUS catheter, evaluation with computational fluid dynamics. Comput Cardiol. 1997;24:597–600.|||Doucette JW, Corl PD, Payne HM, Flynn AE, Goto M, Nassi M, Segal J. Validation of a Doppler guide wire for intravascular measurement of coronary-artery flow velocity. Circulation. 1992;85:1899–1911.|||Berne RM, Levy MN. Cardiovascular Physiology. 8. St. Louis, MO: Mosby; 2001.|||Levy MN, Share L. The influence of erythrocyte concentration upon the pressure-flow relationships in the dog’s hind limb. Circ Res. 1953;1:247–255.|||Shah RK. Laminar Flow Forced Convection in Ducts. New York: Academic; 1978.|||Bhattach S, Tiu C. Developing pressure profiles for non-Newtonian flow in an annular duct. AIChE J. 1974;20:154–158.|||Stone PH, Coskun AU, Kinlay S, Clark ME, Sonka M, Wahle A, Ilegbusi OJ, Yeghiazarians Y, Popma JJ, Orav J, Kuntz RE, Feldman CL. Effect of endothelial shear stress on the progression of coronary artery disease, vascular remodeling, and in-stent restenosis in humans: In vivo 6-month follow-up study. Circulation. 2003;108:438–444.|||Van Oudheusden B. Silicon thermal flow sensor with a two-dimensional direction sensitivity. Meas Sci Technol. 1990;1:565–575.