Quick Links

Publications:

Agreement between upper-arm and wrist cuff occlusion for the assessment of vascular reactivity by digital thermal monitoring.

Authors: Hamidreza Mohammadi|||Ali Hashemi|||Timothy O'Brien|||Hamed Ghoshouni|||Hirofumi Tanaka|||Robert A Kloner|||Morteza Naghavi

Journal: Frontiers in physiology

Publication Type: Journal Article

Date: 2026

DOI: PMC13696328

ID: 42935552

Affiliations:

Affiliations

    American Heart Technologies, Houston, TX, United States.|||American Heart Technologies, Houston, TX, United States.|||Temperature Specialists Inc., St. Francis, MN, United States.|||American Heart Technologies, Houston, TX, United States.|||The University of Texas at Austin, Austin, TX, United States.|||Huntington Medical Research Institutes, Pasadena, CA, United States.|||American Heart Technologies, Houston, TX, United States.

Abstract

Digital Thermal Monitoring (DTM) is an automated method for assessing vascular reactivity using the vascular reactivity index (VRI), a temperature-derived surrogate marker associated with endothelial function. Standard DTM requires five minutes of supra-systolic upper-arm cuff occlusion, which may cause discomfort and limit feasibility in some individuals. Whether wrist cuff occlusion provides comparable VRI measurements remains unknown.


Reference List

    Ahmadi N., Hajsadeghi F., Gul K., Vane J., Usman N., Flores F., et al. (2008). Relations between digital thermal monitoring of vascular function, the Framingham risk score, and coronary artery calcium score. J. Cardiovasc. Comput. Tomogr. 2, 382–388. doi:  10.1016/j.jcct.2008.09.001|||Ahmadi N., Usman N., Shim J., Nuguri V., Vasinrapee P., Hajsadeghi F., et al. (2009). Vascular dysfunction measured by fingertip thermal monitoring is associated with the extent of myocardial perfusion defect. J. Nucl. Cardiol. 16, 431–439. doi:  10.1007/s12350-008-9044-y|||Akhtar M. W., Kleis S. J., Metcalfe R. W., Naghavi M. (2010). Sensitivity of digital thermal monitoring parameters to reactive hyperemia. J. Biomech. Eng. 132, 051005. doi:  10.1115/1.4001137|||Berry K. L., Skyrme-Jones R. A. P., Meredith I. T. (2000). Occlusion cuff position is an important determinant of the time course and magnitude of human brachial artery flow-mediated dilation. Clin. Sci. 99, 261–267. doi:  10.1042/cs0990261|||Bland J. M., Altman D. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327, 307–310. doi:  10.1016/s0140-6736(86)90837-8|||Charakida M., Masi S., Lüscher T. F., Kastelein J. J., Deanfield J. E. (2010). Assessment of atherosclerosis: the role of flow-mediated dilatation. Eur. Heart J. 31, 2854–2861. doi:  10.1093/eurheartj/ehq340|||Daiber A., Steven S., Weber A., Shuvaev V., Muzykantov V., Laher I., et al. (2017). Targeting vascular (endothelial) dysfunction. Br. J. Pharmacol. 174, 1591–1619. doi:  10.1111/bph.13517|||Dhindsa M., Sommerlad S. M., DeVan A. E., Barnes J. N., Sugawara J., Ley O., et al. (2008). Interrelationships among noninvasive measures of postischemic macro- and microvascular reactivity. J. Appl. Physiol. (1985) 105, 427–432. doi:  10.1152/japplphysiol.90431.2008|||Doshi S. N., Naka K. K., Payne N., Jones C. J., Ashton M., Lewis M. J., et al. (2001). Flow-mediated dilatation following wrist and upper arm occlusion in humans: the contribution of nitric oxide. Clin. Sci. (Lond) 101, 629–635. doi:  10.1042/cs1010629|||Dri E., Lampas E., Lazaros G., Lazarou E., Theofilis P., Tsioufis C., et al. (2023). Inflammatory mediators of endothelial dysfunction. Life. 13, 1420. doi:  10.3390/life13061420|||Hadi H., Carr C., Suwaidi A. (2005). Endothelial dysfunction: Cardiovascular risk factors, therapy, and outcome. Vasc. Health Risk Manage. 1, 183–198. doi:  10.2147/vhrm.s12187331|||Heath M., Gourley D., Naghavi M., Klies S., Tanaka H. (2021). Digital thermal monitoring techniques to assess vascular reactivity following finger and brachial occlusions. J. Clin. Hypertension 23, 122–127. doi:  10.1111/jch.14115|||Hsieh H., Liu C.-A., Huang B., Tseng A., Wang D. (2014). Shear-induced endothelial mechanotransduction: the interplay between reactive oxygen species (ROS) and nitric oxide (NO) and the pathophysiological implications. J. Biomed. Sci. 21, 3. doi:  10.1186/1423-0127-21-3|||Kawaja A., Moosa A. S., Lee E. K. P., Phoon I. K. Y., Ang A. T. W., Chang Z. Y., et al. (2025). Comparison of patients’ acceptance of cuff-based vs wearable 24-hour ambulatory blood pressure monitoring devices: A multi-method study. PloS One 20, e0336961. doi:  10.1371/journal.pone.0336961|||Komori T., Eguchi K., Hoshide S., Williams B., Kario K. (2013). Comparison of wrist-type and arm-type 24-h blood pressure monitoring devices for ambulatory use. Blood Pressure Monit. 18, 57–62. doi:  10.1097/mbp.0b013e32835d124f|||Ley O., Dhindsa M., Sommerlad S. M., Barnes J. N., Devan A. E., Naghavi M., et al. (2011). Use of temperature alterations to characterize vascular reactivity. Clin. Physiol. Funct. Imaging 31, 66–72. doi:  10.1111/j.1475-097X.2010.00981.x|||Libby P., Ridker P. M., Maseri A. (2002). Inflammation and atherosclerosis. Circulation 105, 1135–1143. doi:  10.1161/hc0902.104353|||Mahapatra A., Siddiqui M. S., Haseeb M., Sangle A. L., Ingale V., Joshi P. M., et al. (2026). Accuracy assessment of a wrist-worn oscillometric blood pressure device applied to the upper arm in children. Cureus 18, e110605. doi:  10.7759/cureus.110605|||Mannion T. C., Vita J. A., Keaney J. J., Benjamin E. J., Hunter L., Polak J. F. (1998). Non-invasive assessment of brachial artery endothelial vasomotor function: the effect of cuff position on level of discomfort and vasomotor responses. Vasc. Med. 3, 263–267. doi:  10.1177/1358836x9800300401|||McQuilkin G. L., Panthagani D., Metcalfe R. W., Hassan H., Yen A. A., Naghavi M., et al. (2009). Digital thermal monitoring (DTM) of vascular reactivity closely correlates with Doppler flow velocity. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc 2009, 1100–1103. doi:  10.1109/iembs.2009.5333962|||Mućka S., Miodońska M., Jakubiak G., Starzak M., Cieślar G., Stanek A. (2022). Endothelial function assessment by flow-mediated dilation method: A valuable tool in the evaluation of the cardiovascular system. Int. J. Environ. Res. Public Health 19, 11242. doi:  10.3390/ijerph191811242|||Naghavi M., Kleis S., Tanaka H., Yen A. A., Zhuang R., Gul A., et al. (2022). High frequency of microvascular dysfunction in US outpatient clinics: A sign of high residual risk? Data from 7,105 patients. Int. J. Vasc. Med. 2022, 4224975. doi:  10.1155/2022/4224975|||Naghavi M., Yen A. A., Lin A. W., Tanaka H., Kleis S. (2016). New indices of endothelial function measured by digital thermal monitoring of vascular reactivity: Data from 6084 patients registry. Int. J. Vasc. Med. 2016, 1348028. doi:  10.1155/2016/1348028|||Palatini P., Longo D., Toffanin G., Bertolo O., Zaetta V., Pessina A. C. (2004). Wrist blood pressure overestimates blood pressure measured at the upper arm. Blood Pressure Monit. 9, 77–81. doi:  10.1097/00126097-200404000-00004|||Segal S. S. (2005). Regulation of blood flow in the microcirculation. Microcirculation 12, 33–45. doi:  10.1080/10739680590895028|||Thijssen D., Bruno R., Van Mil A., Holder S., Faita F., Greyling A., et al. (2019). Expert consensus and evidence-based recommendations for the assessment of flow-mediated dilation in humans. Eur. Heart J. 40(30):2534–2547. doi:  10.1093/eurheartj/ehz350|||Unlu O., Cannon C. P., Lee S., Gabovitch D., Zelle D., Chin N., et al. (2025). Continual versus occasional blood pressure (COOL-BP) in remote hypertension management. Am. J. Hypertens. 38, 295–302. doi:  10.1093/ajh/hpaf003|||Xu S., Ilyas I., Little P., Li H., Kamato D., Zheng X., et al. (2021). Endothelial dysfunction in atherosclerotic cardiovascular diseases and beyond: From mechanism to pharmacotherapies. Pharmacol. Rev. 73, 924–967. doi:  10.1124/pharmrev.120.000096|||Zeng W., Chan S. W., Tomlinson B. (2021). Patient preferences for ambulatory blood pressure monitoring devices: Wrist-type or arm-type? PloS One 16, e0255871. doi:  10.1371/journal.pone.0255871